top of page
Canadian Solar EP Cube battery with solar system on a home.jpg

All ABB Inverter Error Codes and How to Fix Them

There are approximately 60 ABB inverter error codes that fall into three broad categories ranging from simple warnings to errors and failures. Most common ABB models are PVI-3.0 / PVI-3.6 / PVI-4.2 TL-OUTD Solar Inverter.

We are a local service provider for all ABB Solar Inverter

We can process ABB Solar Inverter warranty claims

Our ABB Solar Inverter Technicians are trained and certified

We offer Hybrid Solar Battery Inverter upgrade options

Schedule a Solar Inverter Repair Technician Today!

Start now with a consultation!

Call (951) 308-1800

What are Solar Inverter Error Codes?

Solar inverter error codes are alphanumeric symbols and signs generated and displayed by an inverter to notify of an issue threatening the normal operation of a solar system. 

​

The inverter is a vital component of a solar system. After the PV modules convert sunlight to solar electricity, the solar inverter converts the electricity to a form that is usable in the house.

 

In that respect, the main function of a solar inverter is power conversion. They convert the DC power the panels produce into AC power that household appliances can use.

​

However, modern inverters do more than just power conversion. Modern solar inverters are smart devices that can also monitor solar PV system performance and give real-time reports.

​

The inverter error codes are examples of the reporting function of solar inverters. 

​

Various forces can affect a solar system’s power generation. When the inverter, in its monitoring capacity, detects an issue, it generates and displays a code to notify you of the problem so that you can take appropriate action. 

​

True, the component of the solar system that is most likely to fail is the inverter. However, “inverter error codes” are not always issues with inverters.

​

Inverter error codes could also represent:

  • Issues with other components of the solar system (like the solar panel), or

  • External problems (such as grid outages).

​

This collection of potential hazards which affect power generation are collectively called “inverter error codes” because the inverter is the device that detects and displays them. 

 

Common Causes of ABB Inverter Error Codes

The most common causes of ABB inverter error codes are:

  • Grid Issues

  • Electrical Current Problems

  • Temperature Fluctuations

  • Software Troubles

ABB PVI-3.0/ 3.6/ 4.2-TL-OUTD Solar Inverter.png
Electricity Station

1. Grid Issues

If you have a grid-tied solar system, inverter error codes can come from grid issues. Inverters are built to operate within specific parameters. If the inputs from the grid are outside those parameters, the inverter will generate and display an error code. 

Grid-related events that cause error codes include:

  • If the grid standard is not set on the inverter,

  • The grid voltage is outside the inverter’s range (over voltage or under voltage), or

  • Grid frequency is above the inverter’s capacity (over frequency or under frequency).

2. Electrical Current Problems

If the input and/or output current is outside the allowable range of the inverter, it will display an error code. Thus, current problems that cause error codes include:

  • Input (DC) overcurrent or undercurrent, or

  • Output (AC) overcurrent or undercurrent.

3. Temperature Fluctuations 

Inverters have an operating temperature range. The inverter will display an error code if the internal temperature or ambient temperature exceeds this range. Thus, temperature problems that cause error codes include:

  • Broken fan,

  • Excessive temperature inside the inverter, or

  • Low ambient temperature.

Solar Panels Technician
Energy Savings Calculator

4. Software Troubles

An inverter makes use of software programs to execute specific tasks. Any problem with the operating information will result in an error message. Examples of software troubles that cause error codes include:

  • Communication breakdown between internal components,

  • An excessive difference between the Internal time of microprocessors and the time displayed, or

  • The inverter takes longer than usual to start up.

All Error Codes for ABB Inverters and Solutions to Fix Them

ABB inverters use three means to display errors. It either displays a code, an error message, or an LED signs (or a combination of these). The ABB solar inverters have about sixty error codes, which can be broadly grouped into three main areas:

  • In the first group, no code is displayed. 

  • In the second group, the error codes begin with a “W.”

  • In the third group, the error codes begin with an “E.”

​

ABB Error Codes – No Code is Displayed

In the first group of ABB inverter error codes, an error message and an LED display are shown, but no alphanumeric code is displayed. 

​

The codes, possible causes, and solutions are as follows:

Code
Error Message
LED Signal
Cause
Solution
W012
Batt. Flat
Yellow
The buffer battery’s voltage is too low.
Check if the date and time are correct. Then switch off the inverter for a few minutes before restarting. If the date time resets to 01/01/2000, replace the battery.
W011
Bulk YV
Yellow
The voltage at the heads of the bulk capacitors is below the inverter’s operation threshold.
Raise the Vstart to sufficient power when the inverter connects to the grid. If the input voltage is less than the Vstart, check for sufficient irradiation. If it exceeds the Vstart, contact customer support.
W010
Fan Broken!
Yellow
The inverter’s internal cooling fan is malfunctioning.
Contact customer support.
W009
Empty Table
Yellow
The characterisation board for the wind generator is not compiled.
Contact customer support.
W003
Grid Failure
Yellow
The grid voltage is absent or outside the inverter’s operating range.
Check for the presence of grid voltage on the supply point. Contact the grid operator to change the parameters if it is present but is either too high or too low. If it’s within the inverter’s range, contact ABB customer service.
W002
Input UV
Yellow
Low voltage when you switch off the inverter.
If the input voltage is lower than normal, check for sufficient irradiation. If it exceeds the operating range, contact customer support.
W001
Sun Low
Yellow
Low input voltage when you switch on the inverter because the modules are incorrectly configured.
If the input voltage is lower than normal, check for sufficient irradiation. If it exceeds the operating range, contact customer support.
None
Awaiting Sun
Green
The input voltage is less than the activation voltage (Vstart).
If the input voltage is lower than the Vstart, esnure that there’s sufficient irradiation.If it exceeds the Vstart, contact customer support.
None
Mem. broken
Yellow
There’s a communication problem with the memory board on which daily energy production is saved
Remove the memory board and check that its connector terminals are intact before reinserting. If the problem persists, contact customer support.
None
Vac absent
Yellow
The inverter is not recording output voltage.
Check that the grid voltage on the inverter’s AC terminal block is present and that there’s grid voltage on the supply point.
None
Set Country or No Nation
None
The grid standard was not set when the inverter was installed.
Set your country’s grid standard. If the error persists, contact customer support.
None
New Component Refused
Yellow
The components inside the inverter are not interlinked due to a component being replaced.
Link the components (using Settings> Service> Accept boards). If the error persists, contact customer support

Will I Need to Replace My ABB Inverter?

ABB inverters are durable devices with a sizable product lifespan. However, since no device is entirely fail-proof, an ABB inverter will sometimes suffer from software or hardware issues. Most ABB inverter issues require full replacements.

How to Claim a Warranty Replacement for an ABB Inverter?

Since FIMER has acquired ABB's solar inverter business, you may be wondering how you can obtain a warranty replacement for your ABB solar inverter if it's still under warranty. The good news is that FIMER is honoring all existing warranties of ABB.

​

The ABB inverters come standard with a 5-year relacement warranty with an option to extend it to 10-years for a fee. Since FIMER absorbed the company in 2019, many ABB inverters are still under the original manufacture warranty. 

Electrician
Pacific Sun Technologies Reference Installations across California

Contact Us Today

Take your first steps in creating a brighter future

Pacific Sun is a wonderful company! They were so informative and never "pushed" a sale on us, which I appreciate! They were always there to answer any questions we had and the team of installers were timely, neat and we hardly knew they were there! Would highly recommend this company! Honest, ethical and always very friendly!
​
- Joanna O.

WHAT OUR

CUSTOMERS SAY

bottom of page