top of page
Canadian Solar EP Cube battery with solar system on a home.jpg

All ABB Inverter Error Codes and How to Fix Them

There are approximately 60 ABB inverter error codes that fall into three broad categories ranging from simple warnings to errors and failures. Most common ABB models are PVI-3.0 / PVI-3.6 / PVI-4.2 TL-OUTD Solar Inverter.

We are a local service provider for all ABB Solar Inverter

We can process ABB Solar Inverter warranty claims

Our ABB Solar Inverter Technicians are trained and certified

We offer Hybrid Solar Battery Inverter upgrade options

Schedule a Solar Inverter Repair Technician Today!

Start now with a consultation!

Call (951) 308-1800

What are Solar Inverter Error Codes?

Solar inverter error codes are alphanumeric symbols and signs generated and displayed by an inverter to notify of an issue threatening the normal operation of a solar system. 

​

The inverter is a vital component of a solar system. After the PV modules convert sunlight to solar electricity, the solar inverter converts the electricity to a form that is usable in the house.

 

In that respect, the main function of a solar inverter is power conversion. They convert the DC power the panels produce into AC power that household appliances can use.

​

However, modern inverters do more than just power conversion. Modern solar inverters are smart devices that can also monitor solar PV system performance and give real-time reports.

​

The inverter error codes are examples of the reporting function of solar inverters. 

​

Various forces can affect a solar system’s power generation. When the inverter, in its monitoring capacity, detects an issue, it generates and displays a code to notify you of the problem so that you can take appropriate action. 

​

True, the component of the solar system that is most likely to fail is the inverter. However, “inverter error codes” are not always issues with inverters.

​

Inverter error codes could also represent:

  • Issues with other components of the solar system (like the solar panel), or

  • External problems (such as grid outages).

​

This collection of potential hazards which affect power generation are collectively called “inverter error codes” because the inverter is the device that detects and displays them. 

 

Common Causes of ABB Inverter Error Codes

The most common causes of ABB inverter error codes are:

  • Grid Issues

  • Electrical Current Problems

  • Temperature Fluctuations

  • Software Troubles

ABB PVI-3.0/ 3.6/ 4.2-TL-OUTD Solar Inverter.png
Electricity Station

1. Grid Issues

If you have a grid-tied solar system, inverter error codes can come from grid issues. Inverters are built to operate within specific parameters. If the inputs from the grid are outside those parameters, the inverter will generate and display an error code. 

Grid-related events that cause error codes include:

  • If the grid standard is not set on the inverter,

  • The grid voltage is outside the inverter’s range (over voltage or under voltage), or

  • Grid frequency is above the inverter’s capacity (over frequency or under frequency).

2. Electrical Current Problems

If the input and/or output current is outside the allowable range of the inverter, it will display an error code. Thus, current problems that cause error codes include:

  • Input (DC) overcurrent or undercurrent, or

  • Output (AC) overcurrent or undercurrent.

3. Temperature Fluctuations 

Inverters have an operating temperature range. The inverter will display an error code if the internal temperature or ambient temperature exceeds this range. Thus, temperature problems that cause error codes include:

  • Broken fan,

  • Excessive temperature inside the inverter, or

  • Low ambient temperature.

Solar Panels Technician
Energy Savings Calculator

4. Software Troubles

An inverter makes use of software programs to execute specific tasks. Any problem with the operating information will result in an error message. Examples of software troubles that cause error codes include:

  • Communication breakdown between internal components,

  • An excessive difference between the Internal time of microprocessors and the time displayed, or

  • The inverter takes longer than usual to start up.

All Error Codes for ABB Inverters and Solutions to Fix Them

ABB inverters use three means to display errors. It either displays a code, an error message, or an LED signs (or a combination of these). The ABB solar inverters have about sixty error codes, which can be broadly grouped into three main areas:

  • In the first group, no code is displayed. 

  • In the second group, the error codes begin with a “W.”

  • In the third group, the error codes begin with an “E.”

​

ABB Error Codes – No Code is Displayed

In the first group of ABB inverter error codes, an error message and an LED display are shown, but no alphanumeric code is displayed. 

​

The codes, possible causes, and solutions are as follows:

Code
Error Message
LED Signal
Cause
Solution
E027
Error Meas V
Yellow
Error in grid voltage internal measurement resulting in grid voltage outside of range.
Contact customer service.
E028
Error Meas F
Yellow
Error in grid frequency’s internal measurement resulting in grid frequency outside of range.
Contact customer service.
E029
Mid Bulk OV
Yellow
Over-voltage on mid bulk’s measurement in triphase models.
Contact customer service.
E030
Error Meas leak
Yellow
High leakage current on the inverter’s DC side.
Contact customer service.
E031
The
Yellow
The internal voltage on the heads of the output relay is outside of the range
Contact customer service.
E032
Error Read I
Yellow
The output currents are not balanced
Contact customer service.
E033
UTH
Yellow
The temperature outside the inverter is below -25 degrees Celsius.
Wait for the temperature to return to the normal operating range. If the problem persists, contact customer service.
E034
Interlock fail
Yellow
The circuitry of the IGBT is not ready.
Contact customer service.
E035
Remote Off
Yellow
The inverter has been remotely switched off.
Remotely switch the inverter back on. If the error persists, contact customer service.
E036
Vout Avg error
Yellow
The grid voltage average measurements are outside of the range.
Check the grid voltage. If it is outside of the inverter’s range, ask the grid operator to adjust it.
E037
Riso Low
Red
The “Amorphous” mode is on, causing a low level of insulation resistance.
Check that the terminals of the grounding resistance are in contact. Measure the insulation resistance. If the value measured is lower than one megaohm, a check is necessary to identify and correct the problem. If the value is greater than 1 megaohm, contact customer support.
E046
String self-test fails
None
An inverted string is recorded during the automatic check of the string voltages record.
Check the polarity of the string recorded as inverted. Then connect all strings correctly and restart the system. If the error persists, contact customer service.

Will I Need to Replace My ABB Inverter?

ABB inverters are durable devices with a sizable product lifespan. However, since no device is entirely fail-proof, an ABB inverter will sometimes suffer from software or hardware issues. Most ABB inverter issues require full replacements.

How to Claim a Warranty Replacement for an ABB Inverter?

Since FIMER has acquired ABB's solar inverter business, you may be wondering how you can obtain a warranty replacement for your ABB solar inverter if it's still under warranty. The good news is that FIMER is honoring all existing warranties of ABB.

​

The ABB inverters come standard with a 5-year relacement warranty with an option to extend it to 10-years for a fee. Since FIMER absorbed the company in 2019, many ABB inverters are still under the original manufacture warranty. 

Electrician
Pacific Sun Technologies Reference Installations across California

Contact Us Today

Take your first steps in creating a brighter future

Pacific Sun is a wonderful company! They were so informative and never "pushed" a sale on us, which I appreciate! They were always there to answer any questions we had and the team of installers were timely, neat and we hardly knew they were there! Would highly recommend this company! Honest, ethical and always very friendly!
​
- Joanna O.

WHAT OUR

CUSTOMERS SAY

bottom of page